Can electroporation previous to radiofrequency hepatic ablation enlarge thermal lesion size? A feasibility study based on theoretical modelling and in vivo experiments

dc.contributor.authorTrujillo Guillén, Macarenaca
dc.contributor.authorCastellví Fernández, Quimca
dc.contributor.authorBurdío Pinilla, Fernandoca
dc.contributor.authorIvorra Cano, Antoni, 1974-ca
dc.contributor.authorAndaluz, Annaca
dc.contributor.authorSanchez Velazquez Patriciaca
dc.contributor.authorBerjano, Enrique J.ca
dc.date.accessioned2016-05-05T14:11:43Z
dc.date.available2016-05-05T14:11:43Z
dc.date.issued2013ca
dc.description.abstractPurpose: To assess the feasibility of a hybrid ablative technique based on applying electroporation (EP) pulses just before conducting radiofrequency ablation (RFA). The rationale was that the EP-induced reduction in blood perfusion could be sufficient to reduce the thermal sink effect and hence to increase the coagulation volume in comparison to that created exclusively by RFA./nMaterials and methods: Modeling study and in vivo experimental study. A Cool-tip RF applicator was used both for EP and RFA./nResults: Overall, the results did not show any synergy effect from using the hybrid technique. Applying EP pulses prior to RFA did not increase the coagulation zone obtained and the lesions were almost identical. Additional computer simulations provided an explanation for this; the effect of reducing blood perfusion by thermal damage during RFA completely masks the effect of reducing blood perfusion by EP. This is because both thermal damage and EP affect the same zone, i.e. the tissue around the electrode./nConclusions: Our computer modeling and in vivo experimental findings suggest that the combination of EP and RFA with monopolar applicators does not provide an additional benefit over the use of RFA alone.en
dc.description.sponsorshipThis work received financial support from the Spanish “Plan Nacional de I+D+I del Ministerio de Ciencia e Innovación” Grants No. TEC2011-27133-C02-01,02 and TEC2010-17285, from the European Commission through the Marie Curie IRG grant TAMIVIVE (256376) and from the Universitat Politècnica de València (INNOVA11-01-5502; and PAID-06-11 Ref. 1988). The linguistic revision of this paper was funded by the Universitat Politècnica de València, Spain.
dc.format.mimetypeapplication/pdfca
dc.identifier.citationTrujilo M, Castellví Q, Burdío F, Sánchez-Velázquez P, Ivorra A, Andaluz A, Berjano E. Can electroporation previous to radiofrequency hepatic ablation enlarge thermal lesion size? A feasibility study based on theoretical modelling and in vivo experiments. Int J Hyperthermia. 2013;29(3):211-18. DOI:10.3109/02656736.2013.777854ca
dc.identifier.doihttp://dx.doi.org/10.3109/02656736.2013.777854
dc.identifier.issn0265-6736ca
dc.identifier.urihttp://hdl.handle.net/10230/26252
dc.language.isoengca
dc.publisherTaylor & Francis (Routledge)ca
dc.relation.ispartofInternational journal of hyperthermia. 2013;29(3):211-18.
dc.relation.projectIDinfo:eu-repo/grantAgreement/ES/3PN/TEC2011-27133-C02-01
dc.relation.projectIDinfo:eu-repo/grantAgreement/ES/3PN/TEC2011-27133-C02-02
dc.relation.projectIDinfo:eu-repo/grantAgreement/EC/FP7/256376
dc.rights© Taylor & Francis. This is an electronic version of an article published in Trujilo M, Castellví Q, Burdío F, Sánchez-Velázquez P, Ivorra A, Andaluz A, Berjano E. Can electroporation previous to radiofrequency hepatic ablation enlarge thermal lesion size? : a feasibility study based on theoretical modelling and in vivo experiments. Int J Hyperthermia. 2013;29(3):211-18. International Journal of Hyperthermia is available online at: www.tandfonline.com http://dx.doi.org/10.3109/02656736.2013.777854ca
dc.rights.accessRightsinfo:eu-repo/semantics/openAccessca
dc.subject.keywordElectroporationen
dc.subject.keywordRadiofrequency ablation
dc.titleCan electroporation previous to radiofrequency hepatic ablation enlarge thermal lesion size? A feasibility study based on theoretical modelling and in vivo experimentsca
dc.typeinfo:eu-repo/semantics/articleca
dc.type.versioninfo:eu-repo/semantics/acceptedVersionca

Files

Original bundle

Now showing 1 - 1 of 1
Loading...
Thumbnail Image
Name:
Trujillo_IntJHype29_Can.pdf
Size:
579.52 KB
Format:
Adobe Portable Document Format