In vitro mitomycin C absorption and delivery with different sponge materials used in filtering surgery.
Mostra el registre complet Registre parcial de l'ítem
- dc.contributor.author Urbaneja, Dianaca
- dc.contributor.author Morilla-Grasa, Antonioca
- dc.contributor.author Jiménez, Elisaca
- dc.contributor.author Montemayor, Judithca
- dc.contributor.author Marcobal Barbara, Nuriaca
- dc.contributor.author Aragay Suñol, M. Carmenca
- dc.contributor.author Gurdiel Fernández, Celiaca
- dc.contributor.author Armillas García, Martaca
- dc.contributor.author Ortiz Sagrista, Pereca
- dc.contributor.author Antón López, Alfonsoca
- dc.date.accessioned 2016-07-12T11:39:18Z
- dc.date.available 2016-07-12T11:39:18Z
- dc.date.issued 2016
- dc.description.abstract PURPOSE: The purpose of this study is to evaluate and compare mitomycin C (MMC) absorption and delivery in different materials used in filtering surgery. METHODS: This is an in vitro study comparing polyvinyl alcohol triangular sponges (TS6, TS8), polyvinyl alcohol fluid wicks (EFW), and absorbable gelatin sponges (AGS3, AGS5), from which five different types of transport units were obtained. Seven pieces of sponge of each transport unit type were obtained as follows: two transverse strips were obtained at 6 and 8 mm from the apex of TS and divided into three equal pieces; 4×4 mm pieces of EFW; 3×3 and 5×5 mm pieces of absorbable gelatin sponges were cut. Filter paper was placed on a precision scale (0.01 mg). The seven sponge pieces of each type were weighed three times consecutively in dry and wet states, the latter after immersion for 15 seconds in 0.2 mg/mL MMC. The difference between the weights of the dry and wet filter paper at the end of each measurement sequence was also calculated and considered as an estimate of the amount of mitomycin delivered. RESULTS: The amounts of MMC absorbed by each transport unit were as follows: (mean ± standard deviation) 27.43±5.13 for TS6, 31.91±6.63 for TS8, 15.96±2.23 for EFW, 17.96±2.05 for AGS3, and 33.81±2.05 for AGS5. The amounts of MMC delivered to the filter paper were as follows: 21.70±2.84 for TS6, 23.83±4.03 for TS8, 12.93±1.75 for EFW, 14.69±1.79 for AGS3, and 27.30±1.58 for AGS5. CONCLUSION: Percentage MMC delivered was similar for all materials, but there was a tendency for greater delivery using larger sponges and greater homogeneity in delivery with AGS5. No statistical differences were found in percentage delivered by the different transport materials.ca
- dc.format.mimetype application/pdfca
- dc.identifier.citation Urbaneja D, Morilla-Grasa A, Jimenez E, Montemayor J, Marcobal N, Aragay C. et al. In vitro mitomycin C absorption and delivery with different sponge materials used in filtering surgery. Clin Ophthalmol. 2016 Apr 15;10:665-9. doi: 10.2147/OPTH.S101345ca
- dc.identifier.doi http://dx.doi.org/10.2147/OPTH.S101345
- dc.identifier.issn 1177-5467
- dc.identifier.uri http://hdl.handle.net/10230/27031
- dc.language.iso catca
- dc.publisher Dove Medical Pressca
- dc.relation.ispartof Clinical Ophthalmology. 2016 Apr 15;10:665-9
- dc.rights 2016 Urbaneja et al. This work is published and licensed by Dove Medical Press Limited. The full terms of this license are available at https://www.dovepress.com/terms.phpand incorporate the Creative Commons Attribution – Non Commercial (unported, v3.0) License (http://creativecommons.org/licenses/by-nc/3.0/). By accessing the work you hereby accept the Terms. Non-commercial uses of the work are permitted without any further permission from Dove Medical Press Limited, provided the work is properly attributed.ca
- dc.rights.accessRights info:eu-repo/semantics/openAccessca
- dc.rights.uri https://creativecommons.org/licenses/by-nc/3.0/ca
- dc.subject.other Glaucomaca
- dc.title In vitro mitomycin C absorption and delivery with different sponge materials used in filtering surgery.ca
- dc.type info:eu-repo/semantics/articleca
- dc.type.version info:eu-repo/semantics/publishedVersionca