Technical validation of real-world monitoring of gait: a multicentric observational study

Mostra el registre complet Registre parcial de l'ítem

  • dc.contributor.author Mazzà, Claudia
  • dc.contributor.author Carsin, Anne-Elie
  • dc.contributor.author García Aymerich, Judith
  • dc.contributor.author Koch, Sarah
  • dc.contributor.author Rochester, Lynn
  • dc.date.accessioned 2022-04-28T05:48:50Z
  • dc.date.available 2022-04-28T05:48:50Z
  • dc.date.issued 2021
  • dc.description.abstract Introduction: Existing mobility endpoints based on functional performance, physical assessments and patient self-reporting are often affected by lack of sensitivity, limiting their utility in clinical practice. Wearable devices including inertial measurement units (IMUs) can overcome these limitations by quantifying digital mobility outcomes (DMOs) both during supervised structured assessments and in real-world conditions. The validity of IMU-based methods in the real-world, however, is still limited in patient populations. Rigorous validation procedures should cover the device metrological verification, the validation of the algorithms for the DMOs computation specifically for the population of interest and in daily life situations, and the users' perspective on the device. Methods and analysis: This protocol was designed to establish the technical validity and patient acceptability of the approach used to quantify digital mobility in the real world by Mobilise-D, a consortium funded by the European Union (EU) as part of the Innovative Medicine Initiative, aiming at fostering regulatory approval and clinical adoption of DMOs.After defining the procedures for the metrological verification of an IMU-based device, the experimental procedures for the validation of algorithms used to calculate the DMOs are presented. These include laboratory and real-world assessment in 120 participants from five groups: healthy older adults; chronic obstructive pulmonary disease, Parkinson's disease, multiple sclerosis, proximal femoral fracture and congestive heart failure. DMOs extracted from the monitoring device will be compared with those from different reference systems, chosen according to the contexts of observation. Questionnaires and interviews will evaluate the users' perspective on the deployed technology and relevance of the mobility assessment. Ethics and dissemination: The study has been granted ethics approval by the centre's committees (London-Bloomsbury Research Ethics committee; Helsinki Committee, Tel Aviv Sourasky Medical Centre; Medical Faculties of The University of Tübingen and of the University of Kiel). Data and algorithms will be made publicly available. Trial registration number: ISRCTN (12246987).
  • dc.description.sponsorship We acknowledge support from the Spanish Ministry of Science and Innovation through the “Centro de Excelencia Severo Ochoa 2019-2023” Program (CEX2018-000806-S), and support from the Generalitat de Catalunya through the CERCA Program. SDD, AY and LRo are also supported by the Newcastle Biomedical Research Centre (BRC) based at Newcastle upon Tyne and Newcastle University. CM, BS, LVG and EB are also supported by the Sheffield Biomedical Research Centre (BRC) based at the Sheffield Teaching Hospital and the University of Sheffield. The work was also supported by the NIHR/Wellcome Trust Clinical Research Facility (CRF) infrastructure at Newcastle upon Tyne Hospitals NHS Foundation Trust and the CRF at the Sheffield Teaching Hospital. The views expressed are those of the author(s) and not necessarily those of the NIHR or the Department of Health and Social Care or the funders.This study was co-funded by the European Union’s Horizon 2020 research and innovation programme and EFPIA via the Innovative Medicine Initiative 2 (Mobilise-D project, grant number IMI22017-13-7-820820). The views expressed are those of the authors and not necessarily those of the IMI, the European Union, the EFPIA, or any Associated Partners. We acknowledge the support of Grünenthal GmbH via the funding of a PhD scholarship directly dedicated to the technical validation protocol.
  • dc.format.mimetype application/pdf
  • dc.identifier.citation Mazzà C, Alcock L, Aminian K, Becker C, Bertuletti S, Bonci T et al. Technical validation of real-world monitoring of gait: a multicentric observational study. BMJ Open. 2021 Dec 2;11(12):e050785. DOI: 10.1136/bmjopen-2021-050785
  • dc.identifier.doi http://dx.doi.org/10.1136/bmjopen-2021-050785
  • dc.identifier.issn 2044-6055
  • dc.identifier.uri http://hdl.handle.net/10230/52923
  • dc.language.iso eng
  • dc.publisher BMJ Publishing Group
  • dc.relation.ispartof BMJ Open. 2021 Dec 2;11(12):e050785
  • dc.relation.projectID info:eu-repo/grantAgreement/EC/H2020/820820
  • dc.rights © Author(s) (or their employer(s)) 2021. Re-use permitted under CC BY-NC. No commercial re-use. See rights and permissions. Published by BMJ. http://creativecommons.org/licenses/by-nc/4.0/. This is an open access article distributed in accordance with the Creative Commons Attribution Non Commercial (CC BY-NC 4.0) license, which permits others to distribute, remix, adapt, build upon this work non-commercially, and license their derivative works on different terms, provided the original work is properly cited, appropriate credit is given, any changes made indicated, and the use is non-commercial. See: http://creativecommons.org/licenses/by-nc/4.0/.
  • dc.rights.accessRights info:eu-repo/semantics/openAccess
  • dc.rights.uri http://creativecommons.org/licenses/by-nc/4.0/
  • dc.subject.keyword Chronic airways disease
  • dc.subject.keyword Heart failure
  • dc.subject.keyword Hip
  • dc.subject.keyword Multiple sclerosis
  • dc.subject.keyword Parkinson-s disease
  • dc.title Technical validation of real-world monitoring of gait: a multicentric observational study
  • dc.type info:eu-repo/semantics/article
  • dc.type.version info:eu-repo/semantics/publishedVersion