Welcome to the UPF Digital Repository

Clinical efficacy and safety of a new hybrid radiofrequency electrode for treatment of liver malignancies : Phase I and phase II randomized clinical trial using radiofrequency versus microwave ablation

Show simple item record

dc.contributor.author Radosevic, Aleksandar, 1974-
dc.contributor.other Burdío Pinilla, Fernando
dc.contributor.other Quesada Diez, Rita
dc.contributor.other Universitat Pompeu Fabra. Departament de Ciències Experimentals i de la Salut
dc.date.accessioned 2022-06-04T01:31:45Z
dc.date.available 2022-06-04T01:31:45Z
dc.date.issued 2021-06-02
dc.identifier http://hdl.handle.net/10803/671844
dc.identifier.uri http://hdl.handle.net/10230/47857
dc.description.abstract La ablación con radiofrecuencia y microondas son opciones terapéuticas útiles para el tratamiento de tumores malignos hepáticos en pacientes seleccionados. Aunque comparables, sus resultados son todavía inferiores a los obtenidos con cirugía. Se han intentado crear dispositivos capaces de producir ablaciones mayores y con geometrías más favorables. Uno de estos dispositivos es Gnomon, el electrodo híbrido experimental desarrollado por nuestro equipo cuya validación clínica en las fases I y II del ensayo clínico constituye el objeto de esta tesis. Inicialmente confirmamos que este electrodo es seguro para el uso clínico y posteriormente, a través de un estudio randomizado, hemos comparado este electrodo con el sistema de microondas de última generación. Aunque no hemos encontrado mejoría en cuanto a geometría de la zona de ablación, los resultados técnicos y clínicos parecen que están en a la altura de los resultados obtenidos con uno de los sistemas de microondas de última generación.
dc.description.abstract Radiofrequency ablation and MWA have each been reported as offering a useful therapeutic option for the treatment of liver malignancy in selected patients. Although comparable, their results are still inferior to results obtained through surgical resection. Efforts have been made to develop devices that are able to produce larger ablation zones with a more favorable geometry. One of these devices is Gnomon, an experimental hybrid electrode developed by our team whose clinical testing through Phase I and Phase II trials is the object of this thesis. We have initially confirmed that this electrode is safe for clinical use and posteriorly, through a randomized clinical trial, we compared this electrode with the latest generation microwave system. Although we did not confirm improvement of the ablation zone geometry, the technical and clinical outcomes seem to be in the range of those obtained with one of the latest generation of microwave systems.
dc.format application/pdf
dc.format 207 p.
dc.language.iso eng
dc.rights L'accés als continguts d'aquesta tesi queda condicionat a l'acceptació de les condicions d'ús establertes per la següent llicència Creative Commons: http://creativecommons.org/licenses/by/4.0/
dc.rights info:eu-repo/semantics/openAccess
dc.source TDX (Tesis Doctorals en Xarxa)
dc.title Clinical efficacy and safety of a new hybrid radiofrequency electrode for treatment of liver malignancies : Phase I and phase II randomized clinical trial using radiofrequency versus microwave ablation
dc.type info:eu-repo/semantics/doctoralThesis
dc.type info:eu-repo/semantics/publishedVersion
dc.date.modified 2022-06-02T00:00:18Z
dc.subject.keyword Radiofrequency ablation
dc.subject.keyword Microwave ablation
dc.subject.keyword Liver tumors
dc.subject.keyword Hepatocellular carcinoma
dc.subject.keyword Liver metastases
dc.subject.keyword Ablación con radiofrecuencia
dc.subject.keyword Ablación con microondas
dc.subject.keyword Carcinoma hepatocelular
dc.subject.keyword Metástasis hepáticas
dc.subject.keyword 616.3