Parametric study of pulsed field ablation with biphasic waveforms in an in vivo heart model: the role of frequency

dc.contributor.authorGarcia-Sanchez, Tomas
dc.contributor.authorAmorós Figueras, Gerard
dc.contributor.authorJorge, Esther
dc.contributor.authorCampos, María C.
dc.contributor.authorMaor, Elad
dc.contributor.authorGuerra, Jose M.
dc.contributor.authorIvorra Cano, Antoni, 1974-
dc.date.accessioned2022-10-13T06:15:47Z
dc.date.available2022-10-13T06:15:47Z
dc.date.issued2022
dc.descriptionData de publicació electrónica: 30-09-2022
dc.description.abstractBACKGROUND: Pulsed field ablation (PFA) is a novel non-thermal cardiac ablation technology based on irreversible electroporation. Unfortunately, the characteristics of the electric field waveforms used in clinical and experimental PFA are not typically reported. This study examines the effect of the frequency of biphasic waveforms and compares biphasic to monophasic waveforms. METHODS: A total of 29 Sprague-Dawley rats were treated with PFA using an epicardial monopolar electrode. Biphasic waveforms with three different frequencies, 90, 260 and 450 kHz (10 bursts of 100 µs duration at 500 V or 800 V) and monophasic waveforms (10 pulses of 100 µs duration at 500 V) were studied. Collateral neuromuscular stimulation and temperature increase in the point of application were directly measured. Lesion formation was assessed 3 weeks after treatment by histopathologic analysis. Computer simulations were used to estimate the electric field lethal threshold for each condition. A previous in vitro study was performed to draw a complete characterization of the studied dependencies. RESULTS: Morphometric analysis demonstrated a significant association between chronic lesion size and waveform characteristics. For the same voltage level, monophasic waveforms yielded the largest lesions compared to any of the biphasic protocols (p<0.05). Increasing PFA frequency was associated with reduced neuromuscular stimulation but also with reduced ablation efficacy. Maximum absolute temperature increase recorded along a complete treatment was 3 °C. Vascular structures inside the lesions were preserved for all conditions. Computer simulation-based analysis showed that waveform frequency had a graded effect on the lethal electric field threshold, with threshold of 600 V/cm for monophasic waveforms vs. 2000 V/cm for biphasic waveforms with a frequency of 450 kHz. CONCLUSIONS: Frequency is a major determinant of efficacy in biphasic PFA. Our results highlight the critical need of disclosing waveform characteristics when reporting the results of different PFA systems.
dc.description.sponsorshipThis work was partially supported by project (PID2019-110120RBI00/AEI/ 10.13039/501100011033) from the Ministry of Science, Innovation and Universities and the State Research Agency of the Spanish government. This project has received funding from the European Union’s Horizon 2020 research and innovation program under the Marie SkłodowskaCurie grant agreement No 892393 (TACAIRE). Antoni Ivorra gratefully acknowledges financial support by ICREA under the ICREA Academia program.
dc.format.mimetypeapplication/pdf
dc.identifier.citationGarcía-Sánchez T, Amorós-Figueras G, Jorge E, Campos MC, Maor E, Guerra JM, Ivorra A. Parametric study of pulsed field ablation with biphasic waveforms in an in vivo heart model: the role of frequency. Circ Arrhythm Electrophysiol. 2022. 43 p. DOI: 10.1161/CIRCEP.122.010992
dc.identifier.doihttps://doi.org/10.1161/CIRCEP.122.010992
dc.identifier.issn1941-3149
dc.identifier.urihttp://hdl.handle.net/10230/54363
dc.language.isoeng
dc.publisherAmerican Hearth Association
dc.relation.ispartofCirculation: Arrhythmia and Electrophysiology. 2022. 43 p.
dc.relation.projectIDinfo:eu-repo/grantAgreement/ES/2PE/PID2019-110120RBI00
dc.rights© American Hearth Association http://dx.doi.org/10.1161/CIRCEP.122.010992
dc.rights.accessRightsinfo:eu-repo/semantics/openAccess
dc.titleParametric study of pulsed field ablation with biphasic waveforms in an in vivo heart model: the role of frequency
dc.typeinfo:eu-repo/semantics/article
dc.type.versioninfo:eu-repo/semantics/acceptedVersion

Files

Original bundle

Now showing 1 - 1 of 1
Loading...
Thumbnail Image
Name:
GarciaSanchez_cir_para.pdf
Size:
1.48 MB
Format:
Adobe Portable Document Format
Description: