Validity, reliability, and calibration of the physical activity unit 7 item screener (PAU-7S) at population scale

dc.contributor.authorSchröder, Helmut, 1958-
dc.contributor.authorSubirana Cachinero, Isaac
dc.contributor.authorGómez, Santiago Felipe
dc.date.accessioned2022-03-01T07:05:25Z
dc.date.available2022-03-01T07:05:25Z
dc.date.issued2021
dc.description.abstractBackground: Validation of self-reported tools, such as physical activity (PA) questionnaires, is crucial. The aim of this study was to determine test-retest reliability, internal consistency, and the concurrent, construct, and predictive validity of the short semi-quantitative Physical Activity Unit 7 item Screener (PAU-7S), using accelerometry as the reference measurement. The effect of linear calibration on PAU-7S validity was tested. Methods: A randomized sample of 321 healthy children aged 8-16 years (149 boys, 172 girls) from the nationwide representative PASOS study completed the PAU-7S before and after wearing an accelerometer for at least 7 consecutive days. Weight, height, and waist circumference were measured. Cronbach alpha was calculated for internal consistency. Test-retest reliability was determined by intra-class correlation (ICC). Concurrent validity was assessed by ICC and Spearman correlation coefficient between moderate to vigorous PA (MVPA) derived by the PAU-7S and by accelerometer. Concordance between both methods was analyzed by absolute agreement, weighted kappa, and Bland-Altman statistics. Multiple linear regression models were fitted for construct validity and predictive validity was determined by leave-one-out cross-validation. Results: The PAU-7S overestimated MVPA by 18%, compared to accelerometers (106.5 ± 77.0 vs 95.2 ± 33.2 min/day, respectively). A Cronbach alpha of 0.76 showed an acceptable internal consistency of the PAU-7S. Test-retest reliability was good (ICC 0.71 p < 0.001). Spearman correlation and ICC coefficients of MVPA derived by the PAU-7S and accelerometers increased from 0.31 to 0.62 and 0.20 to 0.62, respectively, after calibration of the PAU-7S. Between-methods concordance improved from a weighted kappa of 0.24 to 0.50 after calibration. A slight reduction in ICC, from 0.62 to 0.60, yielded good predictive validity. Multiple linear regression models showed an inverse association of MVPA with standardized body mass index (β - 0.162; p < 0.077) and waist to height ratio (β - 0.010; p < 0.014). All validity dimensions were somewhat stronger in boys compared to girls. Conclusion: The PAU-7S shows a good test-retest reliability and acceptable internal consistency. All dimensions of validity increased from poor/fair to moderate/good after calibration. The PAU-7S is a valid instrument for measuring MVPA in children and adolescents.
dc.format.mimetypeapplication/pdf
dc.identifier.citationSchröder H, Subirana I, Wärnberg J, Medrano M, González-Gross M, Gusi N et al. Validity, reliability, and calibration of the physical activity unit 7 item screener (PAU-7S) at population scale. Int J Behav Nutr Phys Act. 2021 Jul 17;18(1):98. DOI: 10.1186/s12966-021-01169-w
dc.identifier.doihttp://dx.doi.org/10.1186/s12966-021-01169-w
dc.identifier.issn1479-5868
dc.identifier.urihttp://hdl.handle.net/10230/52589
dc.language.isoeng
dc.publisherBioMed Central
dc.relation.ispartofInt J Behav Nutr Phys Act. 2021 Jul 17;18(1):98
dc.rights© The Author(s). 2021 Open Access This article is licensed under a Creative Commons Attribution 4.0 International License, which permits use, sharing, adaptation, distribution and reproduction in any medium or format, as long as you give appropriate credit to the original author(s) and the source, provide a link to the Creative Commons licence, and indicate if changes were made. The images or other third party material in this article are included in the article's Creative Commons licence, unless indicated otherwise in a credit line to the material. If material is not included in the article's Creative Commons licence and your intended use is not permitted by statutory regulation or exceeds the permitted use, you will need to obtain permission directly from the copyright holder. To view a copy of this licence, visit http://creativecommons.org/licenses/by/4.0/. The Creative Commons Public Domain Dedication waiver (http://creativecommons.org/publicdomain/zero/1.0/) applies to the data ma
dc.rights.accessRightsinfo:eu-repo/semantics/openAccess
dc.rights.urihttp://creativecommons.org/licenses/by/4.0/
dc.subject.keywordAccelerometry
dc.subject.keywordChildren and adolescents
dc.subject.keywordSelf-reported physical activity
dc.subject.keywordShort PAQ
dc.subject.keywordValidation
dc.titleValidity, reliability, and calibration of the physical activity unit 7 item screener (PAU-7S) at population scale
dc.typeinfo:eu-repo/semantics/article
dc.type.versioninfo:eu-repo/semantics/publishedVersion

Files

Original bundle

Now showing 1 - 1 of 1
Loading...
Thumbnail Image
Name:
Schroder_ijbnpa_vali.pdf
Size:
916.05 KB
Format:
Adobe Portable Document Format

License

Rights