Projection-based collision detection algorithm for stereoelectroencephalography electrode risk assessment and re-planning
| dc.contributor.author | Higueras-Esteban, Alfredo | |
| dc.contributor.author | Delgado-Martínez, Ignacio | |
| dc.contributor.author | Serrano Pérez, Laura | |
| dc.contributor.author | Infante-Santos, Nazaret | |
| dc.contributor.author | Narváez-Martínez, Alejandra | |
| dc.contributor.author | Principe, Alessandro | |
| dc.contributor.author | Rocamora Zúñiga, Rodrigo Alberto | |
| dc.contributor.author | Conesa Bertrán, Gerardo | |
| dc.contributor.author | Serra, Luis | |
| dc.contributor.author | González Ballester, Miguel Ángel, 1973- | |
| dc.date.accessioned | 2022-06-27T06:31:38Z | |
| dc.date.available | 2022-06-27T06:31:38Z | |
| dc.date.issued | 2021 | |
| dc.description.abstract | Surgical planning is crucial to Stereoelectroencephalography (SEEG), a minimally invasive procedure that requires clinicians to operate with no direct view of the brain. Decisions making involves different clinical specialties and requires analysis of multiple multimodal datasets. We present a DepthMap tool designed to localize, measure, and visualize surgical risk, and an AlternativeFinder tool, designed to search for alternative trajectories maintaining adherence to the initial trajectory with three different re-planning strategies: similar entry, similar target, or parallel trajectory. The two tools transform the 3D problem into the 2D domain using projective geometry and distance mapping. Both use the graphics processing unit (GPU) to create a 2D depth image used by DepthMap for measurement and visualization, and by AlternativeFinder to find alternative trajectories. Tools were tested with 12 SEEG cases using digital subtraction angiography. DepthMap was used to measure vessel distance. AlternativeFinder was then used to search for alternatives. Computation time and displacements of the entry and target points for each trajectory and adherence strategy were recorded. The DepthMap tool found vessels in 118 initial trajectories (out of 145). Ninety alternative trajectories were found to meet the required avascular constraints (average 820K alternatives evaluated per initial trajectory). The average computation time was 449 ms per initial trajectory (77 ms when alternatives were found). The tools presented helped clinicians examine and re-plan SEEG trajectories to avoid vascular risks using three adherence strategies. Quantitative measurement of the adherence shows the potential of this tool for clinical use. | |
| dc.format.mimetype | application/pdf | |
| dc.identifier.citation | Higueras-Esteban A, Delgado-Martínez I, Serrano Pérez L, Infante-Santos N, Narváez-Martínez A, Principe A, Rocamora R, Conesa G, Serra L, González Ballester MA. Projection-based collision detection algorithm for stereoelectroencephalography electrode risk assessment and re-planning. IEEE Access. 2021;9:105180-91. DOI: 10.1109/ACCESS.2021.3099964 | |
| dc.identifier.doi | http://doi.org/10.1109/ACCESS.2021.3099964 | |
| dc.identifier.issn | 2169-3536 | |
| dc.identifier.uri | http://hdl.handle.net/10230/53595 | |
| dc.language.iso | eng | |
| dc.publisher | Institute of Electrical and Electronics Engineers (IEEE) | |
| dc.relation.ispartof | IEEE Access. 2021;9:105180-91. | |
| dc.rights | This work is licensed under a Creative Commons Attribution 4.0 License. For more information, see https://creativecommons.org/licenses/by/4.0/ | |
| dc.rights.accessRights | info:eu-repo/semantics/openAccess | |
| dc.rights.uri | https://creativecommons.org/licenses/by/4.0/ | |
| dc.subject.keyword | Biomedical informatics | |
| dc.subject.keyword | DICOM | |
| dc.subject.keyword | depth electrodes | |
| dc.subject.keyword | epilepsy | |
| dc.subject.keyword | implants | |
| dc.subject.keyword | path planning | |
| dc.subject.keyword | stereoelectroencephalography (SEEG) | |
| dc.subject.keyword | stereotactic surgery | |
| dc.subject.keyword | surgery planning | |
| dc.title | Projection-based collision detection algorithm for stereoelectroencephalography electrode risk assessment and re-planning | |
| dc.type | info:eu-repo/semantics/article | |
| dc.type.version | info:eu-repo/semantics/publishedVersion |
Files
Original bundle
1 - 1 of 1

