Welcome to the UPF Digital Repository

¿Pueden las mediciones 3D derivadas de la DXA lumbar predecir fracturas en las vértebras dorsales?

Show simple item record

dc.contributor.author López Picazo, Mireia
dc.contributor.author Humbert, Ludovic
dc.contributor.author Di Gregorio, Silvana
dc.contributor.author González Ballester, Miguel Ángel, 1973-
dc.contributor.author del Río Barquero, Luis Miguel
dc.date.accessioned 2020-12-11T08:17:35Z
dc.date.available 2020-12-11T08:17:35Z
dc.date.issued 2020
dc.identifier.citation López Picazo M, Humbert L, Di Gregorio S, González Ballester MA, Del Río Barquero MA. ¿Pueden las mediciones 3D derivadas de la DXA lumbar predecir fracturas en las vértebras dorsales? Rev Osteoporos Metab Miner. 2020 Feb 27;12(2):45-52. DOI: 10.4321/S1889-836X2020000200003
dc.identifier.issn 1889-836X
dc.identifier.uri http://hdl.handle.net/10230/45980
dc.description.abstract Objetivo: Valorar la asociación de las mediciónes tridimensionales (3D) derivadas de la absorciometría de rayos X de energía dual (DXA) lumbar con las fracturas osteoporóticas en las vértebras dorsales. Material y métodos: Analizamos retrospectivamente 32 mujeres postmenopáusicas: 16 con fracturas incidentes en las vértebras dorsales y 16 controles sin ningún tipo de fractura. Las DXA lumbares se adquirieron en la visita inicial (es decir, antes del evento de fractura) y se midió la densidad mineral ósea de área (DMOa) en las vértebras L1 a L4. Las mediciónes 3D derivadas de la DXA se evaluaron utilizando un software de modelado 3D (3DSHAPER). La densidad mineral ósea volumétrica (DMOv) se calculó en el hueso trabecular, cortical e integral. También se midió el grosor cortical y la DMO superficial (DMOs) cortical. Las diferencias en las mediciónes derivadas de la DXA entre los grupos de fracturados y controles se evaluaron utilizando una prueba t de Student no pareada. También se calculó la razón de probabilidades (OR) y el área bajo la curva característica operativa del receptor (AUC). Resultados: En el presente estudio casocontrol ajustado por edad no se encontraron diferencias significativas entre los grupos de fracturados y controles en términos de peso (ρ=0,44), altura (ρ=0,25) y DMOa (ρ=0,11). Sin embargo, sí se encontraron diferencias significativas (ρ<0,05) en la DMOv integral y trabecular y en la DMOs cortical. La DMOv trabecular en el cuerpo vertebral fue la medida que mejor discriminó entre ambos grupos, con un AUC de 0,733, respecto a 0,682 para la DMOa. Conclusión: Este estudio muestra la capacidad de los modelos 3D derivados de la DXA lumbar para discriminar entre sujetos con fracturas incidentes en las vértebras dorsales y controles. Es necesario analizar cohortes mayores para determinar si estas mediciónes podrían mejorar la predicción del riesgo de fractura en la práctica clínica.
dc.description.abstract Objective: To assess the relation between threedimensional (3D) measurements obtained by lumbar dual energy Xray absorptiometry (DXA) and osteoporotic fractures in dorsal vertebrae. Material and methods: We analysed retrospectively 32 postmenopausal women, allocated to two groups: 16 women in the experimental group, who presented incident fractures of the dorsal vertebrae, and 16 women in the control group, who did not show any type of fracture. Measurements of the (aBMD) of vertebrae L1 through L4 were taken at the initial visit (i.e., prior to the fracture event) by lumbar dualenergy xray absorptiometries (DXA). 3D measurements obtained by DXA were evaluated using 3D modelling software (3DSHAPER). Volumetric bone mineral density (vBMD) was calculated in the trabecular, cortical and integral bone. Cortical thickness and cortical surface BMD (sBMD) were also measured. Differences in measurements derived from the DXA between the experimental and control groups were assessed using an unpaired Student ttest. The odds ratio (OR) and the area under the receiver operating characteristic curve (AUC) were also determined. Results: In the present ageadjusted casecontrol study, no significant differences were found between the experimental and control groups in terms of weight (ρ=0.44), height (ρ=0.25) and aBMD (ρ=0.11). However, significant differences (ρ<0.05) were found in the integral and trabecular vBMD and in the cortical sBMD. Trabecular vBMD in the vertebral body was the measure that best discriminated between both groups, with an AUC of 0.733, compared to 0.682 of the aBMD. Conclusion: This study shows the ability of 3D models resultant from lumbar DXAs to discern between subjects with incident fractures in the dorsal vertebrae and control subjects. It is necessary to analyse larger cohorts to establish if these measurements could improve the prediction of fracture risk in clinical practice.
dc.description.sponsorship The research that led to these results also received funding from the State Program for Research, Development and Innovation Oriented to the Challenges of Society, Ministry of Economy and Competitiveness (Reference: RTC-2014-2740-1) and from the Eurostars program (project ID: 9 140), financed by the Centre for Industrial and Technological Development, Ministry of Economy and Competitiveness. Furthermore, the author Mirella López Picazo received a FEIOMM grant to present the results of this work at the ASBMR 2018.
dc.format.mimetype application/pdf
dc.language.iso spa
dc.publisher Sociedad Española de Investigación Ósea y del Metabolismo Mineral
dc.relation.ispartof Revista de Osteoporosis y Metabolismo Mineral. 2020 Feb 27;12(2):45-52
dc.rights Este es un artículo publicado en acceso (Open Access) abierto bajo la licencia Creative Commons Attribution Non-Commercial (https://creativecommons.org/licenses/by-nc/3.0/deed.es), que permite su uso, distribución y reproducción en cualquier medio, sin restricciónes siempre que sin fines comerciales y que el trabajo original sea debidamente citado.
dc.rights.uri https://creativecommons.org/licenses/by-nc/3.0/
dc.title ¿Pueden las mediciones 3D derivadas de la DXA lumbar predecir fracturas en las vértebras dorsales?
dc.title.alternative Can 3D measurements obtained by lumbar DXA predict fractures in the dorsal vertebrae?
dc.type info:eu-repo/semantics/article
dc.identifier.doi http://dx.doi.org/10.4321/S1889-836X2020000200003
dc.subject.keyword Modelado 3D
dc.subject.keyword Riesgo de fractura
dc.subject.keyword Osteoporosis
dc.subject.keyword Trabecular
dc.subject.keyword Cortical
dc.subject.keyword Fractura vertebral
dc.subject.keyword Densidad mineral ósea volumétrica
dc.subject.keyword Densidad mineral ósea superficial
dc.subject.keyword 3D modelling
dc.subject.keyword Fracture risk
dc.subject.keyword Osteoporosis
dc.subject.keyword Trabecular
dc.subject.keyword Cortical
dc.subject.keyword Vertebral fracture
dc.subject.keyword Volumetric bone mineral density
dc.subject.keyword Superficial bone mineral density
dc.rights.accessRights info:eu-repo/semantics/openAccess
dc.type.version info:eu-repo/semantics/publishedVersion

Thumbnail

This item appears in the following Collection(s)

Show simple item record

Search DSpace


Advanced Search

Browse

My Account

Statistics

Compliant to Partaking