Benvinguts al Repositori Digital de la UPF

Temporal diffeomorphic free-form deformation: application to motion and strain estimation from 3D echocardiography

Mostra el registre parcial de l'element

dc.contributor.author Craene, Mathieu de
dc.contributor.author Piella Fenoy, Gemma
dc.contributor.author Camara, Oscar
dc.contributor.author Duchateau, Nicolas
dc.contributor.author Silva, Etelvino
dc.contributor.author Doltra, Adelina
dc.contributor.author D'hooge, Jan
dc.contributor.author Brugada, Josep
dc.contributor.author Sitges, Marta
dc.contributor.author Frangi Caregnato, Alejandro
dc.date.accessioned 2012-07-09T09:58:49Z
dc.date.available 2012-07-09T09:58:49Z
dc.date.issued 2011
dc.identifier.citation De Craene M, Piella G, Camara O, Duchateau N, Silva E, Doltra A, D'hooge J, Brugada J, Sitges M, Frangi AF. Temporal diffeomorphic free-form deformation: application to motion and strain estimation from 3D echocardiography. Med Image Anal. 2012;16(2):427-50. DOI: 10.1016/j.media.2011.10.006
dc.identifier.issn 1361-8415
dc.identifier.uri http://hdl.handle.net/10230/16689
dc.description.abstract This paper presents a new registration algorithm, called Temporal Di eomorphic Free Form Deformation (TDFFD), and its application to motion and strain quanti cation from a sequence of 3D ultrasound (US) images. The originality of our approach resides in enforcing time consistency by representing the 4D velocity eld as the sum of continuous spatiotemporal B-Spline kernels. The spatiotemporal displacement eld is then recovered through forward Eulerian integration of the non-stationary velocity eld. The strain tensor is/ncomputed locally using the spatial derivatives of the reconstructed displacement eld. The energy functional considered in this paper weighs two terms: the image similarity and a regularization term. The image similarity metric is the sum of squared di erences between the intensities of each frame and a reference one. Any frame in the sequence can be chosen as reference. The regularization term is based on the/nincompressibility of myocardial tissue. TDFFD was compared to pairwise 3D FFD and 3D+t FFD, both/non displacement and velocity elds, on a set of synthetic 3D US images with di erent noise levels. TDFFD/nshowed increased robustness to noise compared to these two state-of-the-art algorithms. TDFFD also proved to be more resistant to a reduced temporal resolution when decimating this synthetic sequence. Finally, this synthetic dataset was used to determine optimal settings of the TDFFD algorithm. Subsequently, TDFFD/nwas applied to a database of cardiac 3D US images of the left ventricle acquired from 9 healthy volunteers and 13 patients treated by Cardiac Resynchronization Therapy (CRT). On healthy cases, uniform strain patterns were observed over all myocardial segments, as physiologically expected. On all CRT patients, the/nimprovement in synchrony of regional longitudinal strain correlated with CRT clinical outcome as quanti ed by the reduction of end-systolic left ventricular volume at follow-up (6 and 12 months), showing the potential of the proposed algorithm for the assessment of CRT.
dc.description.sponsorship This research has been partially funded by the Spanish Industrial and Technological Development Center (CDTI) under the CENIT Programme (cvREMOD Project), the Spanish Ministry of Science and Innovation (MICINN) and the European Regional Development Fund (ERDF) through the research project STIMATH (TIN2009-14536-C02-01), and the European Community’s Seventh Framework Program (FP7/2007-2013) under the euHeart project (FP7-ICT-2007-2-224495).
dc.format.mimetype application/pdf
dc.language.iso eng
dc.publisher Elsevier
dc.relation.ispartof Medical Image Analysis. 2012;16(2):427-50
dc.rights © Elsevier http://dx.doi.org/10.1016/j.media.2011.10.006
dc.subject.other Cor -- Imatges -- Estudi de casos
dc.subject.other Diagnòstic per la imatge
dc.title Temporal diffeomorphic free-form deformation: application to motion and strain estimation from 3D echocardiography
dc.type info:eu-repo/semantics/article
dc.identifier.doi http://dx.doi.org/10.1016/j.media.2011.10.006
dc.subject.keyword Spatiotemporal registration
dc.subject.keyword Di ffeomorphism
dc.subject.keyword FFD
dc.subject.keyword Strain
dc.subject.keyword 3D ultrasound
dc.relation.projectID info:eu-repo/grantAgreement/EC/FP7/224495
dc.relation.projectID info:eu-repo/grantAgreement/ES/3PN/TIN2009-14536
dc.rights.accessRights info:eu-repo/semantics/openAccess
dc.type.version info:eu-repo/semantics/acceptedVersion

Thumbnail

Aquest element apareix en la col·lecció o col·leccions següent(s)

Mostra el registre parcial de l'element

Cerca


Cerca avançada

Visualitza

El meu compte

Estadístiques

Amb col·laboració de Complim Participem